Case study MiniPlant
Start Up June2016
Capacity 20m3/d
Location ShuyangChina
Background
The growing pollution of our environment is a problem concerning everyone of us.. And legislation is demanding more and more of wastewater quality. Therefore the use of innovative technologies has become indispensable for future-orientated wastewater treatment.
The miniplant be desinged and manufactured,the advantages as below:
Easy to Transport, Move, and Expand
Quick Start-up - Fully Automatic and Mess Free
No additional Shelters needed.
Any Capacity, Any Effluent Requirements.
No Odor – Low Power Requirements.
Challenge
Incoming wastewater is the livestock processing wastewater. This treatment is designed to remove Biological Oxygen Demand (BOD), Total Suspended Solids (TSS), ammonia and from the wastewater.
The Inlet and outlet design values of the MiniPlant as follows:
Parameter | Unit | Inlet values | Outlet values |
COD | mg/L | 3,500 | 60 |
BOD5 | mg/L | 2,000 | 20 |
NH4-N | mg/l | 100 | 10 |
OIL | mg/l | 15 | 10 |
Solution
This MiniPlant consists of three system:DAF, MBBR and Clarifier.
The DAF (Dissolved Air Flotation) treatment stage could remove the relative density which is close to that of water, such as micro suspended matter, colloid, oil and grease. The biological treatment stage is designed to substantially degrade the wastes in the sewage water. Clarifier could remove the detached bio-film
from MBBR tank.
Flow Chart of the Process:
Results
The effluent met the requirements of discharge standard.